9XTendGateway 
9XTendGateway
[1024x907] [2988x2648]
9XTendGateway
Viewed: 2961 times.

Updating Firmware:
Open "melabs Programmer" on the start menu and then start the "melabs Programmer" program and you will see this screen. You may need to set the device, using the drop down menu, to PIC18F6622.
[341x85]

Updating Firmware:


Open "melabs Programmer" on the start menu and then start the "melabs Programmer" program and you will see this screen. You may need to set the device, using the drop down menu, to PIC18F6622.
Viewed: 2766 times.

Updating Firmware:
Open the 9XTendGateway.hex file sent to you by APRS World.
[428x273]

Updating Firmware:


Open the 9XTendGateway.hex file sent to you by APRS World.
Viewed: 2823 times.

Updating Firmware:
With the programming connector insterted into the gateway board, apply side pressure so pins make contact with the board. Then go to "Program" and "Program" or hit Control-P.
[366x198]

Updating Firmware:


With the programming connector insterted into the gateway board, apply side pressure so pins make contact with the board. Then go to "Program" and "Program" or hit Control-P.
Viewed: 2720 times.

Updating Firmware:
Programming connector for firmware updates.
[1024x768] [4000x3000]

Updating Firmware:


Programming connector for firmware updates.
Viewed: 2898 times.

Updating Firmware:
Closeup of in-circuit programming connector. Note that pin one, color black, is on the left.
[1024x768] [4000x3000]

Updating Firmware:


Closeup of in-circuit programming connector. Note that pin one, color black, is on the left.
Viewed: 2684 times.

Testing MODBUS Communications:

At APRS World, we use a program called Modbus Test Pro by Rogue Engineering for testing MODBUS communications with the 9XTendGateway.  Here is a screen shot of communicating with a 9XTendGateway with MODBUS address 1. We are querying 16 analog voltage registers, 40036 through 40067. The results are shown on the middle of the right column.
[878x665]

Testing MODBUS Communications:



At APRS World, we use a program called Modbus Test Pro by Rogue Engineering for testing MODBUS communications with the 9XTendGateway. Here is a screen shot of communicating with a 9XTendGateway with MODBUS address 1. We are querying 16 analog voltage registers, 40036 through 40067. The results are shown on the middle of the right column.
Viewed: 3116 times.

Testing MODBUS Communications:

"Com port options" menu is used to set the serial port speed and other settings.
[898x683]

Testing MODBUS Communications:



"Com port options" menu is used to set the serial port speed and other settings.
Viewed: 2802 times.

Testing MODBUS Communications:

The 9XTendGateway can be configured for either 9600 or 19200 baud. This is where you set the speed.
[416x360]

Testing MODBUS Communications:



The 9XTendGateway can be configured for either 9600 or 19200 baud. This is where you set the speed.
Viewed: 2897 times.

Return to APRS World's main website.

RSS