Sensor Inputs
Counters / Anemometers
- Three digital anemometer inputs
- Supports dry contact switch, hall effect switch, or TTL level signal
- RC low pass filter on each input (fc=159 Hz)
- Inputs pulled to 5 volts with internal 4.7k resistor
- Measures pulses falling edge to falling edge
- Pulse time (100 microsecond resolution)
- Pulse minimum time (100 microsecond resolution)
- Number of pulses since last measurement (2^16 or 0 to 65,535)
- Number of pulses total, resettable (2^32 or 0 to 4,294,967,296)
Analog
- Eight analog inputs, 12 bit (2^12 or 0 to 4095)
- 1 x 0 to 100 volt, connect to input power jack
- 2 x 0 to 5 volt, with 200k pull down resistors (typically wind vanes)
- 1 x 0 to 5 volt, with 4.7k pull up resistor (typically temperature)
- 4 x 0 to 5 volt, with 2.2k pull up resistors
- Accessible on RJ-45 connectors
- Internal 5 volt 0.1% band gap voltage reference
- RC low pass on all inputs (fc=159 Hz)
- Current value at time of sampling
- Average value of configured window
Communications Options
Modbus™ / RS-485
- Modbus™ RTU format
- RS-485 fault protected interface
- 9,600 or 19,200 baud
- Five position screw terminal for RS-485 A, RS-485 B, RS-485 C
- #1 flat screw driver required
- Compatible with our RS485Tap product line
Electrical, Mechanical, and Regulatory
Power
- 9 to 76 volts DC, reverse polarity protected
- Two position pluggable screw terminal for DC+ and DC-
- #1 flat screw driver required
- All sensors inputs have Transient Voltage Suppression (TVS) protection
Weight and Dimensions
- Weight: 125 gram (4.4 oz)
- Overall Dimensions: 84 mm wide, 108 mm tall, 34 mm deep (3.3 x 4.25 x 1.35 in)
Materials
- Case: ABS plastic, flame retardant, UL94V-0
- Circuit board: FR-4, 1.6mm (0.062 in), double sided, plated through holes, solder mask, silk screen, gold plated
Regulatory Compliance
- RoHS compliant, no lead used in manufacture
|